Sound Attenuated Diesel Generators

        

Size
10kW
12kW
15kW
20kW
24kW
ALTERNATOR SPECIFICATIONS
TFW-10KW-4P TFW-12KW-4P TFW-15KW-4P TFW-20KW-4P TFW-24KW-4P
Rated Power (kW)
10
12
15
20
24
Rated Voltage (v)
220; 240/120; 400/230; 380/220
Rated Current (A)
41.6
50
62.5
83.3
100
Rated Frequency (HZ)
50/60
Rated Speed (rpm)
1500/1800
Phase Connection
1-Phase,3-Wires; 3-Phase, 4-Wires
Winding Connection
Star-connected
Excitation Method
Brushless
Insulation Method
F Class
Voltage Regulation Method
AVR
Steady-state Voltage regulation Rate
1%
Degree of Protection
IP23
ENGINE SPECIFICATIONS
295AD
2100AD
395AD
495AD
495AD
Type:
Four stroke, water-cooled, inline, direct injection diesel
Number of Cylinders
2
3
4
Total Displacement (L)
1.63
1.8
2.45
3.26
3.26
Fuel Consumption gr./kw.h
265.2
265.2
252.6
258.4
258.4
Rated Output (hp)
21.7
21.7
32.4
43.2
43.2
Run Time (hours)
24.4
26.4
32.4
43.3
36.1
Air Intake
Naturally Aspired
Starting System
Electric 12V
Governor
Mechanical
UNIT
Dimension L x W x H (cm)
194x94x114 214 x94 x114
225x94x116
Dry Weight (kg)
740
760
882
942
968
Fuel Tank Capacity (L)
62
200
Decibels at 7 M.
70 -72
Protection Devices
Low Oil, High Water Temp., Over Speed, Overload
 
Copyright ©2005 - 2008 China Power To Go INC
Contact
ADD:NO.11, SHIHE RD. HEFEI, 230031, CHINA
PHONE:0086-551-65122859 63665137
Cell Phone:0086-13339287055 13309693543
FAX:0086-551-65122859 63665137
Date
News
Edit
alt
#. Question
#. Question
Answer
Edit To Top
   
Timestamp - User

 
  Previous   Next  

Index